APC PDU

Trends and Applications of Smart Power Distributors (PDUs) in Data Centers ( Part 2)

III. Application Scenarios and Pain Point Solutions

1. Scenario 1: Energy consumption monitoring and energy efficiency optimization in large data centers

Pain points:

With PDUs scattered across hundreds of racks, energy consumption data is difficult to collect .

Uneven electrical load leads to severe localized overheating;

There is a lack of detailed energy efficiency analysis and optimization basis.

Both are solutions:

Each smart PDU uploads parameters such as current, voltage, power, temperature, and humidity in real time via the network;

By unifying and aggregating data through a unified intelligent monitoring platform, power consumption can be visualized at the rack and data center levels. The system automatically identifies high-energy-consuming nodes, provides energy efficiency optimization suggestions (such as load balancing and off-peak operation), generates energy consumption reports, supports PUE analysis and energy-saving assessment, and helps build green data centers.

Effect:

Achieving transparent energy consumption management at three levels—”rack, area, and server room”—significantly reduces operating costs.

2. Scenario 2: Unmanned Remote Data Center and Emergency Management

Pain points:

Distributed edge data centers are numerous and difficult to maintain ;

The equipment cannot be dealt with in a timely manner after it malfunctions or becomes overloaded ;

Traditional manual inspections are inefficient and risky.

Both are solutions:

The intelligent PDU supports remote insertion control and can remotely restart servers or network devices;

Automatic alarms are triggered in case of anomalies, and real-time notifications are sent via SMS, email, and platform push .

It supports linkage with temperature and humidity sensors and smoke detectors to achieve comprehensive environmental monitoring ;

The platform supports unified management of multiple sites and centrally displays the operating status of all PDUs .

Effect:

This achieves true “unmanned operation,” improving maintenance efficiency and significantly increasing equipment availability.

3. Scenario 3: Power supply protection for high-security data centers

Pain points:

Power grid fluctuations and lightning surges can cause equipment damage .

The risk of cascading failures in the power supply system is high ;

It has extremely high requirements for power supply continuity .

Both are solutions:

Built-in multi-stage surge protection module (SPD) provides surge protection up to 6kV;

Rapid overcurrent and short-circuit disconnection is achieved through current and voltage anomaly detection;

It adopts highly reliable industrial relays and supports dual power supply switching ;

The equipment has multiple international certifications such as UL and CE, ensuring power supply safety .

Effect:

Improved power supply reliability in data centers effectively reduces downtime caused by power supply anomalies.

IV. The digital wave drives the upgrade of data center energy management

From traditional power distribution equipment to intelligent energy management terminals, Beijing Tongwei Technology Co., Ltd. helps data centers achieve the leap “from availability to reliability, from reliability to efficiency, and from efficiency to intelligence” through innovative product design and comprehensive solutions.

In the future, Tongwei Technology will continue to uphold its development vision of “Intelligent Connectivity, Enabling Future Vision,” and will further expand its presence in the fields of intelligent power distribution, energy management, and security protection. It will provide global users with higher standards of power security and a more intelligent energy management experience, and drive data centers toward a green, intelligent, and sustainable future.