summary |
Intelligent and efficient network power protection from entry level to scalable |
Exterior |
runtime.Ideal UPS for servers,point-of-sale,routers,switches,hubs and other
network devices. |
delivery date |
Usually available from stock |
main information |
|
load running time 400Â Â Â watt â‘ |
4 minutes 26 seconds |
Min-Max:40-400 Watts |
|
Maximum used capacity â‘ |
100% |
Main Input Voltage |
230V |
Main Output Voltage |
230V |
Rated power [W] |
400W |
Rated power [VA] |
500VA |
Input Connection Type |
IEC 60320 C14 |
output connection type |
4 IEC 60320 C13 |
Number of rack units |
2U |
Battery Type
Attached equipment |
Li-lon (lithium ion)
Installation Guide |
|
Mounting Bracket
USB Cable |
Battery and Runtime |
|
operation hours |
View Runtime Graph |
efficiency |
View Efficiency Graph â–¡
This graph is based on actual measured runtime data.All measurements are
performed with new,fully charged batteries and a balanced resistive load (PF
=1.0).Actual run times may vary from the values shown in this graph.Actual |
Battery graph comments |
run time depends on several variables,including battery age,battery chargelevel,environmental conditions and characteristics of the connected load. |
Auto-detectable,scalable delay
time |
0 |
Battery design life |
8.10 years |
Battery power in VAH |
44 VAh runtime |
Battery Charging Voltage (Watts) |
10Â Wrated |
universal |
|
Redundant |
No |
physical parameters |
|
color |
Black with silver front bezel |
high |
4.4cm |
width |
43.2 cm |
depth |
23.2 cm |
product weight |
4.1kg |
Mounting preference |
No preference |
installation type |
Rack-mounted |
USBÂ compatible |
Yes |
enter |
|
Input protection type |
Circuit breaker |
Input voltage limit |
208…253V |
Network frequency |
50/60 Hz +/-3 Hz auto detection |
output |
|
harmonic distortion |
Less than 5% |
Maximum configurable power in
VA |
500VA |
Maximum Configurable Power
(Watts) |
400W |
conversion time |
Typically 0.6 seconds:up to 1 second |
topology |
Online interactive |
Waveform type |
Sine wave
50/60 Hz+/-3 Hz synchronized to master frequency |
Output frequency (synchronized
with main frequency) |
|
compliance
certified product |
C-Tick |
|
CE
EAC |
Device Protection Policy |
Lifespan:$150000 |
Standards compliant |
EN/IEC 62040-2:2006/AC:2006
EN/IEC 62040-2:2018 |
environment |
|
sound level |
45 dBA |
working altitude |
0…10000ft |
operating temperature |
0.40℃ |
storage environment temperature |
-15..45℃ |
storage height |
0.00..7620.00 m |
IP protection class |
IP20 |
Relative humidity |
0.95 %non-condensing |
storage relative humidity |
0…95 %non-condensing |
Communications   and   Management
control Panel |
|
LED status displays:”Online”,”Battery On”,”Replace Battery”and “Building
Wiring Fault” |
free slot |
0 |
alarm |
Alarm when on battery:distinctive low battery alarm:configurable delays |
Surge protection and filtering |
|
Surge suppression energy |
510J |
filter |
Multi-stage noise filter,compliant with ul1449 standard |
packaging unit |
|
Unit Type of Package 1 |
PCE |
Number of Units in Package 1 |
1 |
Package 1 Height |
16.8 cm |
Package 1 Width |
33.7 cm |
Package 1 Length |
59cm |
Package 1 Weight |
6.49 kg |
contract warranty |
|
Warranty |
5-year repair or replacement service |