| Eaton 5PX1000IRT2UG2 |
| Catalog Number: 5PX1000IRT2UG2 |
|
| Eaton 5PX Gen2 UPS, 1000 VA, 1000 W, Input: C14, Output: (8)
C13, Rack/tower, 2U |
|
| General specifications |
|
|
Product Name |
    Catalog Number |
| Eaton 5PX Gen2 UPS |
    5PX1000IRT2UG2 |
| Model Code |
    UPC |
| Eaton 5PX 1000i RT2U G2 |
    743172104731 |
| Product Length/Depth |
    Product Height |
| 448 mm |
    85.5 mm |
| Product Width |
    Product Weight |
| 438 mm |
    19.6 kg |
| Compliances |
    Certifications |
| IEC/EN 62040-1 |
    CE |
| IEC/EN 62040-2 |
    cTUVus |
| IEC/EN 62040-3 |
    EAC |
| RoHS Compliant |
    Cm |
| REACH |
    UKCA |
| UL 1778 |
    Ukr |
| CSA 22.2 |
    ENERGY STAR certified |
|
| Battery |
Electrical output |
|
| Battery type |
Receptacle
(8) C13 |
| Lead-acid maintenance-free (replaceable)
Runtime graph |
|
| Voltage
230V |
| $row.attributeValue.cdata
Battery replacement |
| Wattage
1000 W |
| User replaceable
Battery quantity |
| Output power factor |
| 4 |
1 |
| Battery management |
Output voltage range
230 V (+6%/-10%)
Output waveform |
| ABM & Temperature compensated charging method (user
selectable), Automatic battery test, deep discharge protection,
automatic recognition of external battery units
Battery rating
12 V / 7 Ah |
| Sine wave |
| Output nominal voltage |
| 230V default (200/208/220/230/240V)
Voltage distortion output (linear load) – max |
| Extended battery capability
Yes |
|
0 |
| Feed type |
| 1 |
| Topology |
| Line-interactive |
| VA rating |
| 1000 VA |
| Electrical input |
Communications |
|
| Input connection
C14 |
|
Includes network card |
| No |
| Input nominal voltage |
Communication |
| 230V default (200/208/220/230/240V)
Nominal frequency |
|
USB port (HID compliant) |
| Serial port (RS232) |
| 50-60 Hz |
Mini-terminal block for |
|
remote On/Off and Remote |
| Input voltage range |
Power Off |
| 160-294 V (adjustable to 150 V-294 V)
Input frequency range |
|
Mini-terminal block for |
| output relay |
| 47-70 Hz (50 Hz system), 56.5-70 Hz (60 Hz system), 40 Hz in
low sensitivity mode |
|
Dry contacts (3 outputs, 1 |
| input, optocoupler, DB9) |
| User interface |
Environmental |
|
| Multilingual graphical LCD display
Potential free switch contact |
|
| Altitude
3000 m |
| Yes |
| Expansion slots |
Noise level |
| One slot for optional communication card
Software compatibility |
<40 dB at 1 meter
Temperature range |
|
| Eaton Intelligent Power Manager, Eaton Intelligent Power
Protector |
0° to 40°C (32° to 104°F), batteries recommended max. 25°C
(77°F) |
| Type of interface |
Relative humidity |
| Other |
0-90% non-condensing |
| Additional specifications |
|
| Construction type |
| 482.6 mm (19 inch) device |
| Package contents |
|
Rack-mounting kit |
|
| (2) Supports for tower |
| mounting |
| Cable locking system |
| USB cable |
| Serial cable |
| (2) IEC-IEC cables |
| Quickstart guide |
| Safety instructions |
| Phase (output) |
| 1 |
| Auto shutdown function |
| Yes |
| Color |
| Black/silver |
| Efficiency |
| 98 |
| Rack mounting kit |
| Yes |
| Phase (input) |
| Resources |
|
| Brochures |
| Eaton UPS Services Quick Guide 2021 |
| Eaton UPS and battery services |
| Compliance information |
| Eaton 5PX Gen2 – EU Declaration of Conformity |
| Manuals and user guides |
| Eaton 5PX Gen2 – Quickstart guide |
| Eaton 5PX Gen2 – Advanced User Guide_EN |