Specifications
Eaton DX-RT UPS
6-10 kW
Industrial Gateway Card
(INDGW-M2)
DX-RT 6-10kW is a true online double conversion rack and tower convertible UPS system that affordably
provides robust, reliable, compact and efficient power management solution for mission critical application   from downtime and data–loss.
High efficiency and performance
-      Rack&Tower convertible, higher power density (only 2u and <600mm depth for 10K)
-      TrueOutputUnity PF 1 (VA=Watts)
-      Doubleconversionefficiency up to 95%
-      Achieve>98%in ECO/ high-efficiency mode
- Â Â Â Â Â Supportparalleling
- Â Â Â Â Â Comply withCEcertification
-      Getclearinformation on the UPS’measurements and status with the graphical LCD display
-      Upto100 event log can be read through LCD
-      Easily communicate with theUPS throughUSB, RS232 serial, EPO, programmable dry in/ dry out or over the network with
-      Equipped withEaton’sIntelligent Power™ Software for   seamless integration with all major OS and virtualization platforms.
- IT,Storage, Networking and Server equipment
- Â Â TelecommunicationsandVoIPÂ equipment
- Small andMicro Data Centre application
- Bio-Metrics,Radiology and Medical equipment
- Laboratoryequipment and Precision instruments
- Banking andSecurity system
- Manufacturing
-      Adjustablechargercurrent and set the most suitable charger current in a range of 0 to 12 Amps
-      Meet thelongbackup time requirement with flexible battery configuration of 16-20 pcs battery configuration
-      Extendruntime withconfigurable 3U standard battery module or third-party battery pack
-      Suitable formostinstallations with tower or rack standard 19-inch cabinet
Rating (VA/W)                                              6KVA/6KW                         6KVA/6KW                      10KVA/10KW                    10KVA/10KW | |||||
Format                                                         Tower / Rack | |||||
Input Characteristics | |||||
Input voltage range | 110VAC~275VAC | ||||
Input frequency range | 40~70Hz | ||||
Power factor | ≥ 0.995 | ||||
Harmonic (linear load) | <3% | ||||
Output Characteristics | |||||
Power factor | 1 | ||||
Output voltage | 208 / 220 / 230 / 240VAC (default 220VAC) | ||||
Voltage variation | ±1% | ||||
Output frequency (battery mode) | (50/60±0.1)Hz | ||||
Voltage distortion (linear load) | <1% | ||||
Overload capacity | 105%~125% for 10 minutes; 125%~150% for 30 seconds | ||||
Battery Characteristics | |||||
Type | Valve-controlled maintenance-free lead-acid type | ||||
Battery voltage | 16pcs default (20pcs optional) | 192VDC default (192/ 204/ 216/ 228/ 240VDC adjustable) | 16pcs default (20pcs optional) | 192VDC default (192/ 204/ 216/ 228/ 240VDC adjustable) | |
Backup time – Full load/ 50% load (PF=0.9) | 4 minutes / 11 minutes | depends on battery | 2 minutes / 8 minutes | depends on battery | |
Charger current | 0~4A (default 1.6A) | 0~12A (default 4A) | 0~4A (default 2A) | 0~12A (default 4A) | |
UPS Characteristics | |||||
Efficiency                                                     double conversion mode 95%; ECO mode 98% | |||||
Maintenance bypass switch                            Built-in | |||||
Dimensions W x D x H / Weight | |||||
Dimensions (mm) | 443 x 570 x 87 EBM 443 x 593 x 129 | 443 x 570 x 87 | 443 x 570 x 87 EBM 443 x 593 x 129 | 443 x 570 x 87 | |
Weight (kg) | 13.0 EBM 45.5 | 13.1 | 14.5 EBM 45.5 | 15.0 | |
Operating conditions, Standards and Approvals | |||||
Display | Graphical LCD + LED indicator | ||||
Operating temperature | 0 to 40°C | ||||
Humidity | 0 ~ 95% (no condensation) | ||||
Altitude | <1000m no derating, >1000m derating 1% for every 100m | ||||
Storage temperature | -20 to 55°C (without battery) | ||||
Protection level | IP20 | ||||
Parallel | Support 3 units | ||||
Communication | RS232 /Â USB /Â Network-M2/Â INDGW-M2/Â Relay-MSÂ cards | ||||
Options | Rack mounting rail, EBM, PDU, centralized monitoring software IPM, parallel kit | ||||
Approvals | CE |