Scalable power, runtime & distribution in a high-density, single-frame design. This high-efficiency 3-
phase UPS scales as your data center grows up to 48kW/48kVA. Suitable for small & medium data
center applications. |
Lead time Usually Ships within 2 Weeks |
Main |
Main Input Voltage |
400 V 3 phases |
Main Output Voltage |
230 V
400 V 3 phases |
Other Output Voltage |
380 V
400 V
415 V |
Rated power in W |
32000 W |
Rated power in VA |
32000 VA |
Output connector type |
Hard wire 5-wire (3P + N + E) 1 |
Battery type |
VRLA |
Provided equipment |
Network management card |
|
|
Start-up service |
Batteries & Runtime |
Number of battery filled slots |
3 |
Number of battery free slots |
1 |
Battery recharge time |
3 h |
Number of battery replacement
quantity |
4 |
Additional information |
Configurable for 380 : 400 or 415 V 3 Phase nominal output voltage |
Battery voltage |
+/- 192 V (split battery referenced to neutral) |
Discharge battery voltage |
+/- 154 V |
Overcurrent protection |
756 A |
Maximum short-circuit current |
2 kA |
Max current discharge |
110 A |
Battery charger power |
3445 W rated |
Battery design life 5…8 year(s) |
Sep 6, 2023 |
|
1 |
Battery power in VAH |
10368 VAh runtime |
Battery option |
SYBT9-B4 1 13824 VAh
SYCFXR48-9 1 44928 VAh
SYCFXR48-9 2 76032 VAh
SYCFXR48-9 3 107136 VAh
SYCFXR48-9 4 138240 VAh |
Extended runtime 1 |
General |
Bypass wiring configuration |
5 wire (3P + N + E) |
Bypass voltage tolerance |
+/- 10 % settable from +/- 4/6/8 and 10 % |
Max bypass input current |
80 A |
Bypass current protection |
180 A |
Number of power module free
slots |
0 |
Number of power module filled
slots |
3 |
Redundant |
Yes |
|
Physical |
Colour |
Black |
Height |
199.1 cm |
Width |
60 cm |
Depth |
107 cm |
Net weight |
666.4 kg |
USB compatible |
No |
|
Input |
Network frequency |
40…70 Hz auto-sensing |
Number of input connectors |
1 hard wire 5-wire (3P + N + E) |
Input voltage limits |
340…477 V |
Maximum input current |
65 A |
Switching current capacity |
100 A |
Max short time withstand
current |
30 kA |
Input harmonic distortion |
Less than 5 % for full load |
Input protection type |
GL fuse |
Load power factor |
0.5 leading to 0.5 lagging |
Input Power Factor at Full Load 0.99 |
Output |
Maximum configurable power in
W |
48000 W |
Harmonic distortion |
Less than 2 % |
Output frequency |
50/60 Hz +/- 3 Hz user adjustable +/- 0.1 Hz sync to mains
50 Hz +/- 0.1 % for 50 Hz nominal unsynchronised
60 Hz +/- 0.1 % for 60 Hz nominal unsynchronised |
UPS type |
Double conversion online |
Wave type |
Sine wave |
|
2 |
Sep 6, 2023 |
Output voltage tolerance |
+/- 1% static and +/- 5% at 100% load step |
Output harmonic distortion |
< 2% for 0 to 100% linear load and < 6% for full non-linear load |
Output overload operation |
10 minutes at 125% and 60 seconds at 150% |
Bypass type |
Built-in static bypass |
Efficiency |
95 % (full load)
95 % (half load)
94 % (in battery operation) |
Maximum configurable power in |
48000 VA |
VA |
Conformance |
Product certifications |
EUROBAT |
Standards |
EN 50091-1 |
|
|
EN/IEC 62040-1-1 |
|
EN/IEC 62040-2 |
EN/IEC 62040-3 |
ISO 14001 |
|
ISO 9001 |
VFI-SS-111 |
Environmental |
Ambient air temperature for
operation |
0…40 °C |
Relative humidity |
0…95 % |
Operating altitude |
0…3333 ft |
Ambient air temperature for
storage |
-15…40 °C |
Storage Relative Humidity |
0…95 % |
Storage altitude |
0.00…15240.00 m |
Acoustic level |
61 dBA |
Heat dissipation |
5146 Btu/h |
NEMA degree of protection NEMA 1 |
Communications & Management |
Free slots |
2 |
Preinstalled device |
Network management card with CAN |
Control panel |
Multifunction LCD status and control console |
Emergency power off Yes |
Packing Units |
Unit Type of Package 1 |
PCE |
Number of Units in Package 1 |
1 |
Package 1 Height |
215 cm |
Package 1 Width |
121 cm |
Package 1 Length |
84.8 cm |
Package 1 Weight
Offer Sustainability |
718 kg |
EU RoHS Directive Will be compliant – Date to be confirmed |
Sep 6, 2023 |
3 |
Contractual warranty |
Warranty 1 year on-site repair or replace with factory authorized Start-Up |
Recommended replacement(s) |
4 |
Sep 6, 2023 |